King Circulator Wood Stove Manual

Posted on

• Contract local building or fire officials about restrictions and installation requirements in Do not use this heater in a mobile home or trailer! UNITED STATES STOVE COMPANY 227 Industrial Park Road P.O. Box 151 South Pittsburg, TN 37380 TESTED TO. • You've purchased a heater from North America's oldest manufacturer of wood burning products. By heating with wood you're helping to CONSERVE ENERGY! Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply.

King wood and coal stove. Discussion in 'Firewood, Heating and Wood Burning Equipment' started by Lumberzack, Sep 6. I have the King Wood/Coal circulator.

Plant at least one tree each year. • SAfETY RULES SAFETY NOTICE: If this heater is not properly installed a house fire may result.

For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Read these rules and the instructions carefully. Check with local codes. • LOCATING THE ROOM HEATER as a loCation is seleCteD, KeeP the FolloWinG in minD: Keep the chimney connection as short as possible. The heater must have its own chimney flue. Do not connect any other appliance to the same flue. If there is no chim- ney where you wish to place the heater, you can use a UL Listed Type 103 HT, Solid Fuel, Factory Built Chimney.

• MOUNTING CAST-IRON fLUE COLLAR This heater comes equipped with a cast-iron flue collar with holes to mount the solid damper as shown below. Flue Collar - 40292 Solid Damper - 40398 5/16-18 x 1-1/2' Bolts (3 req.) Weld Tab (3 req.) Gasket. • BLOWER ASSEMBLY for Model 2007B DESCRIPTION Blower Motor Blower Housing Front Blower Housing Back Power Supply Cord Rheostat w/Nut and Knob Strain Relief Bushing 10AB x 3/8 Hex Zinc Screw #12 x 3/4 Teks Screw ASSEMBLY INSTRUCTIONS step 1. The bloWer assemblY must be DisConneCteD From the sourCe oF eleCtriCal suPPlY beFore attemPtinG the installation. • CHIMNEY CONNECTION Two basic types of chimneys are approved for use with solid fuel. Factory-built and masonry.

Stove

Factory-built chimney must comply with UL standard in the US. Do not expect your stove or furnace to create draft. Draft is not a function of the appliance. Draft is purely a function of the chimney. • VENTING INTO A fIREPLACE Many people may wish to convert an existing fireplace to heater use.

Usually, safe connection of stovepipe to a masonry chimney requires more effort than connection to a prefabricated chimney. The fireplace must be tightly closed and sealed at the damper in the flue.

Manual

• VENTING INTO A MASONRY CHIMNEY When considering a masonry chimney, round tiles are preferable to square or rectangular, as round tiles have much better airflow character- istics and are far easier to clean. Unfortunately, most North American chimneys use square or rectangular tile liners that are really designed for open fireplaces, not stoves or furnaces. • 'fIREPLACE' INSTALLATION (CONT'D) fIREPLACE INSTALLATION Connection of the stovepipe directly into the existing masonry chimney over the fireplace opening is a more desirable method. This instal- lation performs better, yielding more heat and better draft; it is also easy to clean and inspect for creosote. • RULES fOR CONNECTOR PIPE INSTALLATION 1.

Crimped end of the pipe must be installed toward the heater. The pipe should slide inside the flue collar. The pipe should be firmly attached to the flue collar with 3 screws and sealed with furnace cement.

• OPERATING INSTRUCTIONS Wood Fuel Use Hardwood that has been split and air-dried to obtain maxi- mum burning efficiency. Lighting instructions Open door and place paper and kindling in the firebox. Light the fire and close the doors until the kindling is burning. Open the doors and add fuel as desired. Description 69427B Ash Pan 40487 Ash Dump Cover 24103 ½ Firebrick 89066 Full Firebrick 69429 Feed Door AC0600 Feed Door Gasket & Silicone PL8535-01 Door Handle 891135 Spring Handle (Nickel) AC09185 Door Barrell/Roller Ball/Pin Assy. 891108 Door Glass 88087 Door Glass Gasket 891114. Insert riGht & leFt siDe FirebriCK as shoWn.

Insert rear FirebriCK as shoWn. Insert bottom 1/2 FirebriCK anD ash DumP CoVer as shoWn.

Contoh Kop Surat – Kop surat adalah bagian terpenting dari setiap surat resmi yang dikeluarkan oleh pemerintah, mulai dari pusat hingga tingkat RT, ataupun perusahaan, mulai dari yang berskala internasional hingga lokal. Contoh kop surat resmi perusahaan di. Contoh Kop Surat Perusahaan – Dalam menjalankan usaha ataupun bisnis, setiap perusahaan tentu akan menggunakan surat resmi sebagai media komunikasi mereka. Surat resmi perusahaan tersebut digunakan untuk keperluan komunikasi internal perusahaan maupun komunikasi eksternal. Karena dengan adanya kop surat, maka surat tersebut terkesan lebih professional, terbukti bahwa surat tersebut surat resmi, dan sekaligus menunjukkan citra perusahaan yang mengirimnya. Sangat berbeda dengan surat pribadi yang terkesan begitu bebas. Kop surat resmi adalah sebuah dari surat yang mana letaknya atau ditulis dibagian atas dalam sebuah surat yang ditulis oleh sebuah perusahaan ataupun instansi resmi. Dalam setiap surat resmi pastinya akan menggunakan kop surat. Contoh Kop Surat. Ada berbagai contoh kop surat yang biasa kita temukan, mulai dari kop surat perusahaan, kop surat sekolah, kop surat yayasan, kop surat intstansi pemerintahan, sampai dengan kop surat lembaga dan organisasi.

WIRING DIAGRAM fOR MODEL 2007B CAUTION! THE BLOWER ASSEMBLY WARNING! MUST BE DISCONNECTED. • Remove ash pan and dump ashes into a safe, noncombustible container. Replace the ash pan after dumping the ashes.

Glass Replacement Instructions for 2007B 1. Be sure heater has cooled before beginning.

Remove 12, 8-32 x ¼ screws and glass re- tainers with screw driver. • THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR 2007B HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.